Which Huahong Floor Is the Most Durable? The Easiest to Clean? The Most Dimensionally Stable?

2026-09-11 - Leave me a message

Seven Types of Anti-static Floors Explained in One Article

The purchase of anti-static floors should not be based on price alone. It is more important to consider the actual requirements of the use scenario in three dimensions: physical performance, cleaning and maintenance cost, and dimensional stability. The following analyzes seven mainstream product categories one by one. Compiled by Guangdong Huahong Floor Co., Ltd. based on many years of industry experience, for reference by domestic and overseas procurement decision-makers.


1. All Steel Ventilation Anti-static Floor

Physical performance: All-steel structure, high mechanical strength, single-panel load up to 2,800 kg, uniform load over 1,600 kg/m². The honeycomb ventilation structure provides an adjustable ventilation rate of 15%–35%, and it is the only product with heat dissipation as its core function. In this category, Guangdong Huahong Floor Co., Ltd. uses high-quality cold-rolled steel sheet, integrally stamped and formed, with evenly arranged ventilation holes. The ventilation rate can be precisely customized according to the heat load of the equipment room.


Cleaning and maintenance: Because the surface has openings, never wash directly with water. Use a vacuum cleaner or a wrung-dry mop to clean, preventing liquid from seeping through the ventilation holes and corroding metal parts underneath. Dust easily accumulates at the edges of the ventilation holes. It is recommended to clean the holes with a soft brush weekly, and every quarter lift the panels to remove dust from the plenum and cables below.


Dimensional stability:The all-steel shell is little affected by ambient temperature changes, with shrinkage less than 0.5 mm and panel deflection less than 0.25 mm. It performs reliably in data centers with constant temperature and humidity year-round.


Application recommendations: Large data centers, high-density server rooms, and AI computing hubs with high heat dissipation requirements.


2. All Steel PVC Anti-static Floor

Physical performance: Composed of an all-steel shell, foamed cement, and PVC surface. The PVC surface is soft and somewhat elastic, with durable anti-static performance, and features wear resistance, dust prevention, aging resistance, and low dust generation. However, its wear resistance is relatively weak, and scratches may appear in long-term high-frequency use areas.


Cleaning and maintenance:The PVC surface is smooth, so dust does not easily adhere. Daily cleaning can be done with a damp mop that is not dripping, together with a neutral detergent. Special attention should be paid to avoiding long-term placement of chairs with black rubber pads, to prevent sulfide contamination of the floor surface. Maintain indoor humidity at 45%–75% RH to prevent the surface from bulging due to overly dry air.


Dimensional stability: PVC surface has excellent ductility and is not prone to curling when the equipment room temperature changes. It is especially suitable for winter heating environments, effectively avoiding cracking of the surface on all-steel floors. Dimensional change on heating ≤0.2%, residual indentation ≤0.15%.


Application recommendations: Class 10–1000 clean workshops, clean rooms, and clean office spaces with appearance requirements.


3. All Steel HPL Anti-static Floor

▶ Physical performance: Uses a melamine high-pressure laminate surface, with surface Mohs hardness ≥4, wear resistance index up to 1,000–3,000 r, scratch resistance more than 3 times that of PVC, and fire performance reaching B1 flame retardant. Suitable for high-frequency inspection areas and places where equipment moves frequently. Guangdong Huahong Floor Co., Ltd. provides HPL products; the bonding strength between the surface and steel plate is high, and edge and corner treatment is smooth, effectively avoiding lifting and delamination.


Cleaning and maintenance: The HPL surface has high hardness and strong pollution resistance. Daily cleaning is mainly with a wrung-dry mop and neutral cleaner. Strictly prohibit strong acid and strong alkali cleaners, to avoid damaging surface gloss and the anti-static coating. It is recommended to apply anti-static floor wax every six months to maintain surface gloss and anti-static performance.


Dimensional stability: Under temperature and humidity changes, dimensional change is small, and expansion or contraction is unlikely. During large-area installation, joints are tight, and gaps or warping are unlikely. However, in northern environments where the day-night temperature difference exceeds 15°C, HPL material is relatively hard, and there may be a risk of surface cracking due to differences in thermal expansion coefficients between the steel plate and the surface.


Application recommendations: Public equipment rooms with high traffic and high-frequency maintenance, and industrial production workshops.


4. All Steel Ceramic Anti-static Floor

▶ Physical performance: Ceramic surface Mohs hardness ≥7, close to natural stone, scratch-resistant, heavy-pressure resistant, and service life can reach over 20 years. Heat resistance up to 200°C, excellent corrosion resistance, completely waterproof, suitable for humid environments. However, a single panel is heavy, so the floor load-bearing structure must be evaluated.


Cleaning and maintenance: Ceramic surface is easy to clean. Daily cleaning with a soft mop or vacuum cleaner is sufficient. Avoid using sharp or hard cleaning tools that may scratch the glaze. Strictly prohibit alkaline detergents, because ceramic components react with alkaline substances. It is recommended to apply ceramic-specific anti-stain wax once a quarter to reduce liquid penetration and stain adhesion. Periodically check whether the grounding system is intact to ensure effective anti-static function.


Dimensional stability: The ceramic surface itself does not deform. Anti-static performance is achieved by adding conductive inorganic materials during high-temperature firing. After physical modification, performance is very stable, with advantages such as fire resistance, environmental friendliness, no deformation, and easy cleaning.


Application recommendations: Semiconductor manufacturing, new energy production workshops, and special industrial scenarios with high-temperature and corrosive environments.


5. OA Network Activity Floor

▶ Physical performance: All-steel combined structure, high mechanical performance, strong load-bearing capacity, and self-weight about 2/3 that of traditional raised floors, which can reduce floor load. Its core function is the strong/weak current separation cable trough design, with excellent electromagnetic shielding performance, effectively reducing electromagnetic interference between cables. The OA Network Activity Floor from Guangdong Huahong Floor Co., Ltd. has a flexible cable trough layout, and outlet ports can be freely added or removed according to workstation adjustments, adapting to the frequent changes of modern offices.


▶ Cleaning and maintenance: Maintenance is extremely convenient. A single panel can be opened independently. Workstation adjustment, line expansion, and troubleshooting only require lifting the corresponding panel. The panel can be kept clean by regular wiping, and the space under the floor can be cleaned through regular inspections. When cleaning, strictly prohibit using hard objects such as iron brushes on the floor surface. Strong current cables and weak current cables must never be mixed in the same trough.


▶ Dimensional stability: Panel width limit deviation is -0.40 mm, panel thickness limit deviation ≤0.3 mm, surface flatness ≤0.6 mm, adjacent edge perpendicularity ≤0.3 mm. Dimensional accuracy is high, interchangeability is good, it does not deform when exposed to moisture, and it is suitable for low raised-height installation.


Application recommendations: Operating rooms in top-tier hospitals, laboratories, and intelligent office spaces.


6. Calcium Sulfate Anti-static Floor

▶ Physical performance: The calcium sulfate core is made by pressing fibers and gypsum crystals. Concentrated load can reach 5,000 N, with outstanding load-bearing capacity. A2 non-combustible standard, excellent fire performance, and system resistance stable at 1×10⁴–1×10¹⁰ Ω.


▶ Cleaning and maintenance: During cleaning, strictly prohibit large amounts of water flushing, to prevent water from penetrating into seams and damaging the core or causing rusting of the base metal. It is recommended to use a wrung-dry mop or special anti-static cleaner. For oil stains, wipe with a neutral cleaner and then clean again with clean water to avoid residue. Anti-static wax can be applied to the floor surface for maintenance.


▶ Dimensional stability: This is the most prominent advantage of calcium sulfate flooring. The molecular structure of the calcium sulfate core is like a micro-sponge; it returns to its original shape after absorbing and releasing water, and does not deform even when soaked in water. Under long-term constant load, creep deformation is extremely low, maintaining dimensional and shape stability for decades, avoiding the uneven panel surface that occurs with traditional floors after long-term use. After 24 hours of immersion in water, deformation is only 0.3%.


Application recommendations: Large power dispatch centers, communication equipment rooms, radio and TV broadcasting studios, and data equipment rooms with high fire protection requirements.


7. Aluminum Alloy Anti-static Floor

▶ Physical performance: Made by one-piece die-casting of aluminum alloy. Density is only 1/3 that of steel, but uniform load can reach 23,000 N/m², concentrated load 4,450 N, with outstanding load-bearing capacity. The material itself meets A1 non-combustible standard, naturally corrosion-resistant, oxidation-resistant, and excellent moisture resistance.


▶ Cleaning and maintenance: Use an anti-static vacuum cleaner daily to remove surface dust, and wet-wipe with neutral cleaner 1–2 times per week. Liquid spills should be absorbed immediately; corrosive liquids should first be covered with fine sand and then cleaned. The surface must not be washed with water. Use a wrung-dry mop to wipe, preventing the decorative surface from peeling and the metal parts underneath from rusting.


▶ Dimensional stability: The aluminum alloy panel base will not deform due to water immersion or moisture, does not corrode, does not rust, and has excellent salt spray resistance. It is especially suitable for humid areas or coastal high-humidity environments. Dimensional accuracy is high, performance is extremely stable, and service life is over 15 years.


Application recommendations: Power dispatch centers with high load-bearing requirements, precision equipment rooms, high-end computing centers, and intelligent office spaces in humid environments.


Quick Selection Comparison Table

Product Physical Performance Highlights Cleaning & Maintenance Difficulty Dimensional Stability Core Application Scenarios
All Steel Ventilation Anti-static Floor Load 2,800 kg, ventilation rate 15–35% Medium (prevent liquid penetration) High High heat-density data centers
All Steel PVC Anti-static Floor Flexible surface, cost-effective Low Relatively high (good ductility) Clean workshops
All Steel HPL Anti-static Floor Wear-resistant 1,500 r, B1 flame retardant Medium High (but attention needed with large temperature differences) High-frequency maintenance equipment rooms
All Steel Ceramic Anti-static Floor Mohs hardness ≥7, resistant to 200°C Low (but special wax required) Extremely high High-temperature corrosive industrial scenarios
OA Network Activity Floor Strong/weak current separation, electromagnetic shielding Extremely low (modular opening) High (high precision) Hospitals/laboratories/offices
Calcium Sulfate Anti-static Floor Load 5,000 N, A2 non-combustible Medium (strictly no water flushing) Extremely high (does not deform when immersed) Power dispatch/radio & TV
Aluminum Alloy Anti-static Floor Uniform load 23,000 N/m² Low Extremely high (moisture and salt spray resistant) Humid/high load-bearing scenarios


When purchasing, it is recommended to first clarify the core constraints of the use environment. If the environment is humid or has corrosion risks, give priority to ceramic or aluminum alloy. If long-term dimensional stability is extremely important, calcium sulfate is the safest choice. If cabling is complex and requires frequent adjustment, the modular design of the OA Network Activity Floor can greatly reduce maintenance costs.

Guangdong Huahong Floor Co., Ltd. has focused on the R&D and production of anti-static floors for many years. Its products cover all categories including all-steel, calcium sulfate, and aluminum alloy. Product parameters are subject to actual orders. Selection consultation, sample testing, and customized solutions can be provided according to project requirements. You are welcome to contact us.